UPS Luminous, a leader in Home UPS category has been consistently delivering world-class products that are preferred not only in India but, globally as well for over 2 decades. Luminous Home UPS are manufactured using latest state-of-the-art technology at a highly automated plant in Himachal Pradesh. Our credential lies in satisfaction of over. Download UPS catalogue, regalia catalogue, Luminous battery caralogues and more from Luminous products catalogue online from our official trusted website. × Email Verification Looks like you haven't provided a valid Email ID. Cruze and Pro UPS Stabilizer Online UPS Systems.
Advertising
+++
**)
Placement
This UPS is intended for indoor use
only;
only;
its internal components are not
sealed
from the environment.
Please install it in a protected
environment away from excessive heat
or excessive moisture.
environment away from excessive heat
or excessive moisture.
Charging the UPS first
The battery is fully charged at the
factory. However, it is recommended to
charge the battery at least 8 (eight)
hours before using the UPS, since
energy loss may have occurred during
shipping or long duration storage. To
recharge the battery, simply leave the
UPS plugged into an AC outlet.
factory. However, it is recommended to
charge the battery at least 8 (eight)
hours before using the UPS, since
energy loss may have occurred during
shipping or long duration storage. To
recharge the battery, simply leave the
UPS plugged into an AC outlet.
Connecting your equipment to the UPS
For UPS models with US-type outlets: connect the power cord(s) of your computer
equipment to the output receptacle(s) of the UPS.
equipment to the output receptacle(s) of the UPS.
For UPS with IEC outlets, as shown in the illustration, use your computer power cord to
connect UPS to the wall socket. Use the power cord supplied with the UPS to connect
your PC to one of UPS outlets (item 1.5 on the rear panel drawing below).
connect UPS to the wall socket. Use the power cord supplied with the UPS to connect
your PC to one of UPS outlets (item 1.5 on the rear panel drawing below).
Turn on the UPS
To turn UPS on please press the power button for 3 seconds. Pressing the power button
shortly under normal mode will enable the self-test function. The silence function can be
enabled/disabled by shortly pressing the power button in backup mode. In addition, the
power button can be used as the master on/off switch for your equipment by leaving your
equipment connected to UPS and switched on. To turn off the UPS, please press power
button for about 3 seconds.
shortly under normal mode will enable the self-test function. The silence function can be
enabled/disabled by shortly pressing the power button in backup mode. In addition, the
power button can be used as the master on/off switch for your equipment by leaving your
equipment connected to UPS and switched on. To turn off the UPS, please press power
button for about 3 seconds.
Warning
DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE
THEY TYPICALLY DRAW TOO MUCH POWER
THEY TYPICALLY DRAW TOO MUCH POWER
Fuse replacement procedure
(Note: for 220V/230V/240V units only)
1. Use a slotted screwdriver to take out the fuse holder
2. Take out the busted fuse from the fuse holder
3. Use the screwdriver to push out the spare fuse from the holder
4. Put the spare fuse in the holder
5. Push the fuse holder back into the AC input socket
6. Follow the UPS turn on procedure
2. Take out the busted fuse from the fuse holder
3. Use the screwdriver to push out the spare fuse from the holder
4. Put the spare fuse in the holder
5. Push the fuse holder back into the AC input socket
6. Follow the UPS turn on procedure
Battery replacement procedure
Note: Follow this procedure for safe replacement of the battery. However, small sparks may occur
during the process. This is normal.
during the process. This is normal.
Luminous Pro Ups 2250 User Manual 2017
1. Turn off the UPS and unplug it from the wall outlet
2. Remove two screws both sides nearby the front panel
3. Gently pull the top portion of the front panel until it unsnaps
4. Place the front panel on top of the unit taking care not to pull out the wires for the panel
5. Remove the screw for the battery cover
6. Gently pull out the batteries using the tab located at the base of the battery
7. Disconnect the two long wires connecting the batteries to the UPS
8. Use the short wire to connect between the batteries and push the new batteries into place
9. Connect the long wires to the new batteries, making sure that the red wire is connected to the red
4. Place the front panel on top of the unit taking care not to pull out the wires for the panel
5. Remove the screw for the battery cover
6. Gently pull out the batteries using the tab located at the base of the battery
7. Disconnect the two long wires connecting the batteries to the UPS
8. Use the short wire to connect between the batteries and push the new batteries into place
9. Connect the long wires to the new batteries, making sure that the red wire is connected to the red
battery terminal of the lower battery and the black wire to the black battery terminal of the upper
battery
battery
10. Mount the battery cover and replace the screw
11. Snap back the front panel into place
12. Follow the UPS turn on procedure
11. Snap back the front panel into place
12. Follow the UPS turn on procedure
Front & Rear Panels
1.1 Power Button 1.5 UPS Outlets
1.2 RS-232 Port
*)
1.6 Surge Suppression Outlet
**)
1.3 Phone/LAN Jack
*)
1.7 Circuit Breaker
1.4 AC Input 1.8 AC Fuse
_____________________________________________
_____________________________________________
*)
TS-B models only
**)
Battery Backup Outlet for TS1700(B) (110V/120V) /
TS2250(B) (110V/120V/220V/230V/240V)
No Load Shutdown Function
As a battery saving feature, the UPS will automatically turn off if none
of the connected equipment is operating while the UPS is in back-up
mode. Once normal utility power returns, the unit will re-start
automatically. You can disable the “No Load Shutdown” function by
pressing the power button of your switched-off UPS until you hear two
beeps.
of the connected equipment is operating while the UPS is in back-up
mode. Once normal utility power returns, the unit will re-start
automatically. You can disable the “No Load Shutdown” function by
pressing the power button of your switched-off UPS until you hear two
beeps.
Front panel LED (UPS status indicator)
AC Mode
When the LED is continuously lit and the
buzzer is silent, the UPS is in normal mode and
providing power to your equipment. The UPS
will continue to filter electrical noise and
provide surge protection.
buzzer is silent, the UPS is in normal mode and
providing power to your equipment. The UPS
will continue to filter electrical noise and
provide surge protection.
Battery Mode
When the LED blinks every 2 seconds in time
with the beeping sound, the UPS is providing
power from its battery.
with the beeping sound, the UPS is providing
power from its battery.
When the LED is flashing rapidly and the
beeping sound is continuous, it indicates that
the UPS is overloaded. https://belyellow985.weebly.com/casio-privia-px-160-user-manual.html.
beeping sound is continuous, it indicates that
the UPS is overloaded. https://belyellow985.weebly.com/casio-privia-px-160-user-manual.html.
www.opti-ups.com
Thunder Shield
User Manual
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Here in this post, we are going to show you the back panel pictures of various leading inverter models available in the market.
- Sukam shiny –Pure sinewave
- Microtek SEBz pure sine wave
- Exide Inverter – Pure sinwave
- Luminous – Pure sinewave
- Amaron – Pure sinewave inverter
Almost all leading inverter models have the same kind of features, but they differ in outlook.
Some companies give different name for the same function in the inverter to differentiate their product from the crowd.
Luminous Pro Ups 2250 User Manual Instructions
So, don’t get confused, we will describe you about the sliding buttons and other functions you see in the back panel of the inverter. No worries!
Back panel of Sukam Shiny Inverter, a pure sine wave model from Su Kam.
In the above picture, there are two switches in between the power output socket and cooling fan.
W-UPS ——–UPS
LA ————-SMF/TUB
Let us explain the functions for the above two switches,
W-UPS means ‘wide UPS’ mode, which means the inverter operates in voltage range of 100 V to 300 Volt.
In this wide UPS mode, the switch over time is little longer compared to ‘UPS’ mode. So, if you use desktop PC connected with Inverter in W-UPS Mode, your PC would restart during power cuts.
It’s better to use UPS mode when connecting your desktop PC with your inverter for power backup. You won’t lose any unsaved data in your computer during power cut.
This UPS mode ——W UPS mode is just similar to voltage selection button in Microtek Inverters.
In simple words,
W UPS – 100 to 300 Volt
UPS – 180 to 260 Volt
There are some advantages and disadvantages in using ‘UPS’ mode.
If you use UPS mode in your inverter, during evening time when the overall power consumption rises, you might face some drop in voltage from grid. If your grid power voltage goes below 180 v , instantly your inverter switch back to battery mode and start using your battery power,
NO power cut required, just a low voltage will trigger your inverter to switch back to Battery mode. This is the big problem with UPS mode in any inverter. If ‘Low voltage’ occurs frequently, then you will end up in low backup or no power backup when the real power shedding happens L
Conclusion
If you plan to use Home UPS for your desktop computer, better you switch on UPS mode button, only when you use your desktop computer. Switch it back to W UPS mode, when you shut down your desktop PC.
W-UPS mode (wide ups mode) or wide voltage mode (100 to 300v) is always safe and gives better battery life. If you don’t use any desktop PC with your inverter, always keep your inverter in W-UPS mode (100to300V) to get better battery backup during power cuts.
Laptop users don’t need to use UPS mode, laptops have internal battery and they don’t reboot during power cutsJ
Battery selection Switch or Charge current selection switch
You will find another important switch in the back panel of Home Ups,
Luminous Pro Ups 2250 User Manual Software
Manual ares build download. Battery selection switch, which is called as charge current selection switch.
—————————————————————
In Sukam shiny
This switch is labeled as LA ——SMF/TUB
LA – Normal charging mode (up to 10 amp)
SMF/TUB – High charge mode (up to 15 amp)
LA means Lead acid battery or Normal Inverter battery.
SMF means Sealed Maintenance free Battery
TUB means Tubular battery (both short and tall tubular)
————————————————————-
1956 farmall super m manual download. LA battery or Normal inverter battery – Most non-tubular inverter batteries comes under this category.
LA mode in Sukam shiny gives only normal and safe charging current (upto 10 amp) to connected battery. This is just a safety measure to ensure long battery life.
But during long and intermittent power shedding, we would recommend using the high charge mode (SMF/TUB) for Normal inverter batteries (non tubular). Slow or standard charging mode won’t quick charge your battery. It is safe to use batteries like ‘Exide inverter plus’ in high charge mode to handle and intermittent power shedding.
Caution: How ever we recommend High charge mode (SMF/TUB) for normal inverter batteries, we also recommend not to use high charge mode for batteries older than 3 years ( both LA and Tubular)
Batteries older than 3 years are not capable of accepting the high charge current (up to 15 amp), there is a risk of battery failure.
Play safe!
This is just a simple job to restore your inverter.
Fuse in the back panel of the inverter may blow at times of high voltage or any other voltage fluctuations in the grid.
NO need to call a technician to replace this fuse. Most inverters are provided with spare fuses. Check your inverter box for spare fuses. Some electricians will take the spare fuses provided with new inverters during installation and they don’t allow the consumer to replace it themselves.
It is a not that much complicated job, you can try it yourself.
Just open the fuse cap at the back panel of inverter (open it like opening a bottle cap), check whether the fuse is blown or intact.
If you find faulty or blown fuse, replace it with new fuse provided with your inverter.
Caution: Switch OFF the mains supply before working on your inverter. Replace the blown fuse with same amp rating, never try with lower or higher amp rating.
—————————————————-
———————————————————--
Most users complain about the reboot problem when using home UPS with desktop computers.
This is not a problem with inverter, you need to set the right mode in inverter before connecting desktop PC to your inverter.
We have already published a article about Microtek back panel switches configuration
Read this article for more on Microtek inverter back panel
—————————————————————————--
Exide inverter has three modes for charge current selection.
To know more details on this
Read this post about Exide Inverter Charge selection Switch
——————————————————————————--
Luminous Inverter backpanel is slightly different from others.
Luminous Pro Ups 2250 User Manual Download
It has two Fuses
Luminous Pro Ups 2250 User Manual Pdf
Charger fuse
Main Fuse
No confusion, luminous has provided two fuses to facilitate the maintenance process.
In Luminous, there is a cap on Charge current selection switch or battery selection switch. This is just a precaution to avoid making frequent changes in charge current selection. As we already said, using high charge current settings for old batteries is not recommended by most inverter manufacturers, so they put a cap on charge current selection switch.
Luminous Pro Ups 2250 Manual
Don’t worry, you can make changes by removing the cap, it’s always safe to use high charge current for new batteries.
In Luminous inverter, you can find this UPS mode – Normal Mode switch with different label
Regulated UPS mode – UPS Mode – Narrow voltage mode – 180 to 260 V
UnRegulated UPS Mode – W UPS mode – Wide voltage mode – 100 to 300 V
Luminous Pro Ups 2250 User Manual Free
Regulated UPS mode is best for using desktop computers with inverter. No reboot problem!
If you don’t use Desktop PC, then Use the default Unregulated UPS mode for better battery backup and performance.